2A800-1G-100

  • 99_Figure_5.jpg
Avionic Instruments designed and qualified the 750VA static inverter product family utilizing current component technology and innovative thermal/mechanical techniques. The design utilizes a two stage conversion electrical topology that provides overall device isolation and excellent load handling capability. The design is able to operate reliably even when installed in extreme thermal and high level vibration installations.
DimensionsWeight
12"L x 8.50"W x 4.10"H 12.50 lbs.

General Specifications
Input Voltage
28 VDC, nominal
22 - 37 VDC, normal

Efficiency
77% Typical at full resistive load minimum from 50% to 100% rated load, nominal

Output Voltage
100 VAC RMS +/- 2%
Single Phase WYE

Output Frequency
600 +/- 1.0%

Overload
110% rated load for 2 hours
120% rated load for 5 min
150% rated load for 5 sec

Output Power
VA, nominal 800

Output Waveshape
THD, typcial 1.00%


Temperature Range
-55° to 71° C operating
Cooling
Integral Cooling Fan

Protection Functions
Output overvoltage
Output over/under frequency
Internal overtemperature
Short circuit
Input over/undervoltage
Input reverse polarity

RTCA-DO Category
RTCA DO-160 A B C D E F G

Avionic INSTRUMENTS LLC 1414 Randolph Avenue PO Box 498 Avenel, NJ 07001